Skip to main content

Reciept Tolerance

We can specify receipt tolerance for an item in item application. This will allow us to receipt  Item more than we define on Po line.

Steps


  1. Specify reciept tolerance for an item and vendor details for example 10.
  2. Create a PO and select vendor specified above, select vendor items to create POLINE with central as storeroom.Specify quantity as 100
  3. Approve PO and Go to recieving application and select above and recieve those items. 
  4. On recieving enter quantity 120 and select OK. Maximo displays a message Quantity specified on PO is greater and quantity ordered and reciept tolerance by 10 Click "OK" to receive 110 Qty.
  5. Go ahead and Create an invoice on this PO an approve it with quantity 110
  6. Go to invoice main tab and you will be able to see invoice amount .Also you will be able to see univoiced quantity which is for those 10 extra items you recieved.
Calculation of Uninvoiced Amount is 

Uninvoice Cost=PoTotalCost-InvoiceTotalCost

We can specify receipt tolerace in POLine table , itemvendor table, item/org details table, inventory table, service items .

Comments

Popular posts from this blog

Maximo Interview Questions - Maximo Technical and Functional Questions

Technical Questions How do you rate your self in :- 1. PL/SQL 2. Java 3. Automation Script 4. Mbo Customization 5. Admininstration Jobs 6. Funtional Concepts 7. Maximo Configuration Do not rate anything less than 7 unless you don't want interview to skip the topic Deployment / Administration  1. Explain LDAP integration? 2. Explain SSO and LTPA token? 3. What is global security? 4. How session is managed in Websphere or Maximo? 16. How to insert attributes from Backend? 5. How request is passed in Maximo? 6. How to do horizontal and vertical clustering? 7. Explain how you confire websphere for maximo manually? 8. What are Websphere MQ? 9. What is JMS, Connection Factory and Queues? 10. What is difference between vmm and ldap sync integration ? 11. What is Standalone and federated repository? 12. How to install a new language in Maximo? 13. What are the steps to apply a Fix pack in Maximo, Websphere or DB2? 14. Have you worked on any performance checking tools? 15...

Maximo Bean Class Methods

Methods of Bean Classes of Maximo Reset Method   This method is called when a new filter is applied for the dialog's MboSet.  @see psdi.webclient.system.beans.DataBean#reset()     @Override     public void reset() throws MXException     {             try         {                 saveCurrentSelection();         }         catch (RemoteException e)         {             handleRemoteException(e);         }         super.reset();     } Initialize It is used to initialize values on a d...

BMXAA4211E - Database error number 1 has occurred when operating mbo...

 BMXAA4211E - Database error number 1 has occurred when operating on WFINSTANCE This solution you can use for any table generic solution in oracle db only  this is duplicate id issue.. (if you cannot remove duplicate just increase nextval like i did since in my case too i can't find duplicate and max value is greater than nextval. select max(WFID) from maximo.wfinstance *select maximo.WFINSTANCESEQ.NEXTVAL from dual; increase you value with some 1000's from o/p of query 1... example *alter sequence maximo.WFINSTANCESEQ restart start with 17572034; Similary if it comes for wfcallstack   BMXAA4211E – Database error number 1 has occurred when operating on WFCALLSTACK:   Report the error to the owner of the deployment.     check maxvalue    select max(wfcallstackid) from maximo.WFCALLSTACK     check next value    select maximo.WFCALLSTACKSEQ.NEXTVAL from dual; increase value by some 10000 etc...... alter sequence max...